Abstract:
OBJECTIVE To develop an HPLC-ELSD method for the determination of lyso-phosphatidylcholine(LPC) and lyso-phosphatidylethanolamine(LPE) in Docetaxel Concentrated Solution for Injection.
METHODS It was separated with YMC Pack PVA-Sil(150 mm×2 mm, 5 μm) by gradient elution with chloroform as mobile phase A and methanol-water (93.5∶6.5) as mobile phase B at a flow rate of 0.4 mL·min
-1. The column temperature was kept at 25 ℃ for separation. The detector was ELSD, of which the drift tube temperature was maintained at 100 ℃ and the flow rate of carrier gas air was kept at 2.0 L·min
-1.
RESULTS The linear response was calculated by logarithm. The calibration curves were linear in the range of 0.203-0.811 μg(
r=0.999 0) for LPE and 0.407-6.102 μg(
r=0.999 6) for LPC. The average recovery for LPE was 104.1%, 95.1%, 101.6%, RSD=4.6%; and the average recovery for LPC was 108.7%, 104.5%, 105.5%, RSD=2.7%.
CONCLUSION The established method is simple, accurate and reproducible, which can be used for the quality control of Docetaxel Concentrated Solution for Injection.