Abstract:
OBJECTIE To establish an ion chromatography method for rapid and precise determination of the content of antioxidant sodium bisulfite in azasetron hydrochloride and sodium chlodide injection. METHODS The AS-11 anion analytical column(4.6 mm×250 mm, 5 μm) was adopted to separate the samples with the eluent of 20 mmol·L
-1 potassium hydroxide. The flow rate was 1.0 mL·min
-1, and the suppressed conductivity detector was adopted. Samples were diluted with 0.4% formaldehyde solution followed by direct injection. RESULTS This method exhibited excellent regression(r=0.9997) in the range of 4.07-30.51 μg·mL
-1 for NaHSO
3 and regression(r=0.999 8) in the range of 1.59-159.0 μg·mL
-1 for Na
2SO
4, the average recovery (n=9) was 98.82%, 98.24%, respectively for NaHSO
3 and Na
2SO
4. CONCLUSION The method is simple, accurate, stable and precise, and can be userd for the determination of sodium bisulfite in azasetron hydrochloride and sodium chlodide injection.