HPLC同时测定复方替硝唑载体栓中3组分含量

    Simultaneous Determination of Three Components in Compound Tinidazole Carrier Suppositories by HPLC

    • 摘要: 目的 建立HPLC同时测定复方替硝唑载体栓中3组分含量。方法 采用Diamonsil C18(200 mm×4.6 mm,5 μm);流动相:甲醇-水-三乙胺(60∶40∶0.5)(用磷酸调pH值至4.0),流速:1.0 mL·min-1,检测波长:260 nm,进样量:20 μL;柱温:25 ℃。结果 复方替硝唑载体栓中3组分替硝唑、克霉唑、醋酸氯己定的线性范围分别为40~600,32~480,1.6~24 μg·mL-1(r=0.999 9),平均回收率分别为99.81%,100.2%,100.3%;RSD分别为0.37%,0.2%和0.4%(n=9)。结论 该方法可同时测定3种成分含量,操作简便、快速,结果准确、可靠。

       

      Abstract: OBJECTIVE To establish an HPLC method to simultaneous determine three components in compound tinidazole carrier suppositories. METHODS A Diamonsil-C18(200 mm×4.6 mm, 5 μm) column was used; the mobile phase was the mixture of methanol-water-triethylamine(60∶40∶0.5)(adjusted by phosphoric acid to pH 4.0), the flow rate was 1.0 mL·min-1, the UV detector was operated at 260 nm, injection volume was 20 μL; column temperature was 25 ℃. RESULTS The linear ranges of three components in compound tinidazole carrier suppositories tinidazole, clotrimazole, chlorhexidine acetate were 40–600, 32–480, 1.6–24 μg·mL-1(r=0.999 9). The average recoveries respectively were 99.81%, 100.2%, 100.3%, and RSDs respectively were 0.37%, 0.2% and 0.4%(n=9). CONCLUSION This method can simultaneously determine three components. It is easy and fast with accurate and reliable results.

       

    /

    返回文章
    返回