低分子量羟丙甲纤维素的分子量及其分布的测定

    Determination of the Molecular Weight and Its Distribution of Low Molecular Weight Hypromellose

    • 摘要: 目的 测定低分子量羟丙甲纤维素的分子量及其分布。方法 利用高效体积排阻色谱-示差折光检测器-多角激光光散射检测器(HPSEC-RID-MALLS)技术,以0.1 mol·L-1硝酸钠-甲醇(95:5)为流动相,采用Shodex OHpak SB-804 HQ(8.0 mm×300 mm)凝胶柱进行检测。结果 低分子量羟丙甲纤维素的重均分子量测定误差≤2%,数均分子量和分子量分布误差均≤5%,结果准确可靠。结论 利用HPSEC-RID-MALLS技术可测定低分子量羟丙甲纤维素的分子量及其分布。

       

      Abstract: OBJECTIVE To determine the molecular weight and its distribution of low molecular weight hypromellose. METHODS High performance size exclusion chromatograghy in conjunction with refractive index detector and eighteen-angle laser light scatter detector(HPSEC-RID-MALLS), was performed on the Shodex OHpak SB-804HQ(8.0 mm×300 mm) column, using 0.1 mol·L-1 sodium nitrate-methanol(95:5) as mobile phase. RESULTS The error of the weight-average molecular weight of low molecular weight hypromellose was ≤2%, and the error of number-average molecular weight and molecular weight distribution of low molecular weight hypromellose were ≤5%. The results were accurate and reliable. CONCLUSION It can be used to determine the molecular weight and its distribution of low molecular weight hypromellose by HPSEC-RID-MALLS.

       

    /