Abstract:
OBJECTIVE To establish a method for simultaneous determination of the content of 5 metal elements(
63Cu,
75As,
114Cd,
202Hg,
208Pb) in Huafeng Dan.
METHODS The samples were digested with concentrated nitric acid-hydrogen peroxide(5:1), and then microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the mass concentration of 5 metal elements.
72Ge,
115In,
209Bi were used as internal standards.
RESULTS The correlation coefficient of the standard curves of 5 elements was >0.999 2, detection limits were in the range of 0.001-0.055 ng·mL
-1, recoveries were in the range of 85.67%-114.14% and RSDs were in the range of 1.12%-4.26%.
CONCLUSION The method is specific, accurate and sensitive, and suitable for the content determination of 5 common metal elements in Huafeng Dan.