Abstract:
OBJECTIVE To establish an HPLC-ELSD method for the determination of morgtoside V in Fufang Luohanguo Zhike granule.
METHODS AlltimaTM-C
18 column(4.6 mm×250 mm, 5 μm), mobile phase: acetonitrile-water(23∶77), column temperature: 30 ℃. ELSD condition: temperature of drift tube: 105 ℃, flow rate of gas: 2.0 mL·min
-1.
RESULTS Morgtoside V was linear in the range of 1.608-9.648 μg, with regression equation of
Y=1.634 3
X+12.591(
r=0.999 7), the average recovery was 101.36%(RSD=1.29%).
CONCLUSION The established method is accurate, specific and reliable for the determination of morgtoside V in Fufang Luohanguo Zhike granule.