Abstract:
OBJECTIVE To establish method for simultaneous determination of disodium cantharidinate and vitamin B
6 in Disodium Cantharidinate and Vitamin B
6 injection.
METHODS HPLC was performed on a Syncronis C
18 column(250 mm×4.6 mm, 5 μm) using the gradient 0.02 mol·L
-1 potassium phosphate monobasic solution(adjust pH to 2.6 with H
3PO
4)(A)-acetonitrile(B) at the 1.0 mL·min
-1 flow rate as mobile phase. The column temperature was 30℃ and the detection wavelengths were 193 nm and 290 nm(wavelength switching).
RESULTS The linear regression equation of disodium cantharidinate was
Y=1.926
X+0.010(
r=0.999 7); the linear range was 0.064 6-0.322 8 mg·mL
-1 with the average recovery of 98.9% and the RSD of 1.2%(
n=9). The linear regression equation of vitamin B
6 was
Y=24.153
X+0.670(
r=0.999 9); the linear range was 0.535 9-2.679 7 mg·mL
-1 with the average recovery of 100.2% and the RSD of 1.0%(
n=9). The RSD values for the instrument precision, stability and repeatability were all <2.0%.
CONCLUSION The established HPLC method appears to be accurate and reproducible, which can be used for the quality control of Disodium Cantharidinate and Vitamin B
6 injection.