    Dissolution Determination of Acetaminophen and Moroxydine Hydrochloride in Ganmaoqing Capsule by HPLC

    • OBJECTIVE To establish the method of dissolution determination of acetaminophen and moroxydine hydrochloride in Ganmaoqing capsule. METHODS Paddle apparatus was used with 0.1 mol·L-1 hydrochloric acid solution as the dissolution medium at a speed of 50 r·min-1 and dissolution time limit was 30 min. The analysis was carried out on a ZORBAX SB-C18(150 mm×4.6 mm, 5 μm) column, the mobile phase was composed of acetonitrile-0.02 mol·L-1 sodium heptanesulfonate(15∶85) at the flow rate of 1.0 mL·min-1 and the detection wavelength was 237 nm. RESULTS Acetamino- phen showed good linearity in the range of 4.588×10-2-0.458 8 μg(r=0.999 8), the average recovery was 98.1% with RSD of 1.06%(n=9); moroxydine hydrochloride showed good linearity at the range of 4.654×10-2-0.465 4 μg(r=0.999 6), the average recovery was 97.9% with RSD of 1.09%(n=9). CONCLUTION The method is convenient, accurate and practicable. It can be applied to determine the dissolution of the preparations.