• 首页期刊简介编委会刊物订阅专栏专刊电子刊广告合作联系我们English
引用本文:裴宇盛,蔡彤,陈晨,高华,祝清芬.重组C因子法检测福沙匹坦二葡甲胺中细菌内毒素的方法学研究[J].中国现代应用药学,2019,36(1):1-4.
PEI Yusheng,CAI Tong,CHEN Chen,GAO Hua,ZHU Qingfen.Methodological Study on the Detection of Bacterial Endotoxin in Fosaprepitant Dimeglumine by Recombinant Factor C[J].Chin J Mod Appl Pharm(中国现代应用药学),2019,36(1):1-4.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2606次   下载 1798 本文二维码信息
码上扫一扫!
分享到: 微信 更多
重组C因子法检测福沙匹坦二葡甲胺中细菌内毒素的方法学研究
裴宇盛1, 蔡彤1, 陈晨1, 高华1, 祝清芬2
1.中国食品药品检定研究院, 北京 100050;2.山东省食品药品检验研究院, 济南 250101
摘要:
目的 建立福沙匹坦二葡甲胺的细菌内毒素检测方法。方法 使用凝胶法、动态显色法、重组C因子法对福沙匹坦二葡甲胺进行方法学研究。结果 凝胶法在检测浓度范围内结果均为阳性结果,不符合凝胶法进行干扰实验的前提。动态显色法中,出现了不同稀释倍数回收率符合药典规定的情况下,内毒素检测结果差异极大(结果差异>200倍),使用了抗增液仍存在该问题。重组C因子法中,当样品浓度<0.062 5 mg·mL-1即不存在干扰作用并且不存在上述问题,结果符合规定。结论 福沙匹坦二葡甲胺无法使用经典的凝胶法和动态显色法进行内毒素检测。重组C因子法经过方法学研究,可以用于福沙匹坦二葡甲胺的内毒素质量控制。
关键词:  细菌内毒素检查  福沙匹坦二葡甲胺  重组C因子法  鲎试剂  干扰实验
DOI:10.13748/j.cnki.issn1007-7693.2019.01.001
分类号:R927.12
基金项目:"重大新药创制"国家科技重大专项(2018ZX09101001-004-005)
Methodological Study on the Detection of Bacterial Endotoxin in Fosaprepitant Dimeglumine by Recombinant Factor C
PEI Yusheng1, CAI Tong1, CHEN Chen1, GAO Hua1, ZHU Qingfen2
1.National Institute for Food and Drug Control, Beijing 100050, China;2.Shandong Institutes for Food and Drug Control, Jinan 250101, China
Abstract:
OBJECTIVE To establish a bacterial endotoxin test method for fosaprepitant dimeglumine. METHODS The methodological study of fosaprepitant dimeglumine was carried out by gel colt method, dynamic chromogenic method and recombinant factor C method. RESULTS The result of gel colt method was positive in the range of detection concentration, which did not meet the premise of the gel colt method for interference experiments. In the dynamic chromogenic method, when the recovery ratio of different dilution multiples met the requirements of the pharmacopoeia, the endotoxin detection results were extremely different(the difference was greater than 200 times), and the problem still existed with the use of endotoxin-specific buffer. When the sample concentration was lower than 0.062 5 mg·mL-1, there was no interference existed, and the results were in compliance with the regulations using recombinant factor C method. CONCLUSION It is not possible to detect endotoxin in fosaprepitant dimeglumine by classical gel method and dynamic chromogenic method. The recombinant factor C method can be used for the endotoxin quality control of fosaprepitant dimeglumine based on the methodology research.
Key words:  bacterial endotoxin test  fosaprepitant dimeglumine  recombinant factor C method  limulus amebocyte lysate  test for interference
扫一扫关注本刊微信