• 首页期刊简介编委会刊物订阅专栏专刊电子刊广告合作联系我们English
引用本文:邹慧龙,王双虎,周云芳.UPLC-MS/MS测定大鼠血浆中8-O-乙酰山栀苷甲酯浓度[J].中国现代应用药学,2016,33(4):440-444.
ZOU Huilong,WANG Shuanghu,ZHOU Yunfang.Determination the Concentration of Barlerin in Rat Plasma by UPLC-MS/MS[J].Chin J Mod Appl Pharm(中国现代应用药学),2016,33(4):440-444.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2188次   下载 1906 本文二维码信息
码上扫一扫!
分享到: 微信 更多
UPLC-MS/MS测定大鼠血浆中8-O-乙酰山栀苷甲酯浓度
邹慧龙1, 王双虎2, 周云芳2
1.丽水市人民医院药学部,浙江 丽水 323000;2.丽水市人民医院临床药学实验室,浙江 丽水 323000
摘要:
目的 建立超高效液相串联质谱法快速测定大鼠体内8-O-乙酰山栀苷甲酯的浓度。方法 用乙腈沉淀蛋白方法处理血浆,色谱柱为ACQUITY UPLC BEH C18柱(50 mm×2.1 mm,1.7 μm);流动相为乙腈-0.1%甲酸水,梯度洗脱,流速为0.4 mL·min-1;用正离子多离子反应监测(MRM)扫描,内标为槲皮素。结果 血浆中8-O-乙酰山栀苷甲酯的线性范围为2.5~500 ng·mL-1(r=0.997 9),最低定量限为0.5 ng·mL-1。低、中、高3个浓度(3, 45和450 ng·mL-1)的质控样品的日内、日间精密度RSD均<10%,3个浓度的相对回收率分别为(103.59±4.75)%, (98.68±4.62)%和(97.06±5.64)%。结论 该方法操作简便、快捷,灵敏度高,适于大鼠血浆中8-O-乙酰山栀苷甲酯浓度的测定及其药代动力学研究。
关键词:  8-O-乙酰山栀苷甲酯  血药浓度  药动学  超高效液相串联质谱法
DOI:
分类号:
基金项目:2015年浙江省医药卫生一般研究计划(2015KYB457)
Determination the Concentration of Barlerin in Rat Plasma by UPLC-MS/MS
ZOU Huilong1, WANG Shuanghu2, ZHOU Yunfang2
1.Department of Pharmacy, People’s Hospital of Lishui City, Lishui 323000, China;2.The Laboratory of Clinical Pharmacy, People’s Hospital of Lishui City, Lishui 323000, China
Abstract:
OBJECTIVE To develop an ultra performance liquid chromatography-tandem mass spectrometry method for the determination of barlerin in rat plasma. METHODS Plasmas were precipitated with 200 μL acetonitrile. An ACQUITY UPLC BEH C18(50 mm×2.1 mm, 1.7 μm) column was used as the stationary phase. The mobile phase was consisted of acetonitrile and 0.1% formic acid water with gradient elution pumped at a flow rate of 0.4 mL·min-1. The analytes were detected with positive electrospray ionization in multiple reaction monitoring(MRM) mode and quercetin was used as internal standard. RESULTS Excellent linear calibration curve of barlerin was obtained in the concentration range of 2.5-500 ng·mL-1(r=0.997 9). The lower limit of quantification were 0.5 ng·mL-1. The intra and inter day relative standard deviations of low, medium and high quality control samples (3, 45 and 450 ng·mL-1) were all <10%. The average recovery were (103.59±4.75)%, (98.68±4.62)% and (97.06±5.64)%. CONCLUSION The method is simple, rapid and sensitive, which is suitable for pharmacokinetics study of barlerin in rats.
Key words:  barlerin  plasma concentration  pharmacokinetics  ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)
扫一扫关注本刊微信