• 首页期刊简介编委会刊物订阅专栏专刊电子刊广告合作联系我们English
引用本文:王晓冲,周继昌,李军,王晓炜,应国红.实时荧光定量PCR方法应用于药品无菌快速检测的研究[J].中国现代应用药学,2013,30(12):1333-1337.
WANG Xiaochong,ZHOU Jichang,LI Jun,WANG Xiaowei,YING Guohong.Real-time Fluorescence PCR Assay for Fast Detection of Drug Sterility Test[J].Chin J Mod Appl Pharm(中国现代应用药学),2013,30(12):1333-1337.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 3673次   下载 2425 本文二维码信息
码上扫一扫!
分享到: 微信 更多
实时荧光定量PCR方法应用于药品无菌快速检测的研究
王晓冲1, 周继昌2, 李军1, 王晓炜1, 应国红1
1.深圳市药品检验所,广东 深圳 518000;2.深圳市慢性病防治中心,广东 深圳 518000
摘要:
目的 建立应用实时荧光定量PCR进行无菌快速检测的方法。方法 选取金黄色葡萄球菌及大肠埃希菌,用裂解试剂盒抽提细菌基因组DNA,进行实时荧光定量PCR检测,并应用叠氮溴化丙锭(PMA)抑制样品中死菌基因组DNA的PCR扩增。结果 PMA能有效去除样品中死菌干扰,针对16S rRNA基因保守序列进行扩增的荧光定量PCR方法具有较高的灵敏度。在金黄色葡萄球菌和大肠埃希氏菌检测中,最低含菌量组与阴性对照组Ct值有明显差异(P<0.05),其最低检出限为2 CFU/PCR。在对人工污染药品的无菌检测中,该方法与药典检测方法结果一致。结论 进行无菌检查时,采用PMA去除样品中死菌基因组DNA干扰,以裂解试剂盒抽提细菌基因组后用荧光定量PCR分析样品中细菌污染,可将检测时间缩短到4 h左右,操作简单,灵敏性高,可应用于药品无菌检查的快速筛查。
关键词:  荧光定量PCR  叠氮溴化丙锭  细菌污染  快速检测
DOI:
分类号:
基金项目:广东省科技计划项目(2011B031500029)
Real-time Fluorescence PCR Assay for Fast Detection of Drug Sterility Test
WANG Xiaochong1, ZHOU Jichang2, LI Jun1, WANG Xiaowei1, YING Guohong1
1.Shenzhen Institute for Drug Control, Shenzhen 518000, China;2.Shenzhen Center for Chronic Disease Control, Shenzhen 518000, China
Abstract:
OBJECTIVE To establish a real-time PCR assay to fast detect bacterial contamination in drugs. METHODS Staphylococcus aureaus and Escherichia coli were used as representative, and the bacterial genomic DNA was isolated by lysis buffer kit and then quantitatively detected by Taqman real-time PCR. Propidium monoazide (PMA) was used as a pretreatment for the DNA molecules in dead cells and inhibited the PCR amplification of the DNA molecules. RESULTS PMA treatment was effective and the real-time PCR targeting conservative 16S rRNA gene showed high sensitivity. The Ct value of the lowest bacterial dose groups in both S. aureaus and E. coli were statistically different from the negative control with a minimal detection quality of 2 CFU/PCR. The result of real-time PCR was accordant to the pharmacopoeia test in the sterile test of contaminated drugs. CONCLUSION The lysis buffer kit used to extract bacterial genomic DNA with subsequent real-time PCR is convenient and sensitive, and may be applied to fast detection of drug sterility test.
Key words:  real-time fluorescence quantitative PCR  propidium monoazide (PMA)  bacterial contamination  fast detection
扫一扫关注本刊微信