• 首页期刊简介编委会刊物订阅专栏专刊电子刊广告合作联系我们English
引用本文:丁文宇,雷勇胜,傅琳,穆帅,陈蔚,潘毅.GC-MS/MS测定索法酮中基因毒性杂质异亚丙基丙酮含量[J].中国现代应用药学,2021,38(14):1686-1689.
DING Wenyu,LEI Yongsheng,FU Lin,MU Shuai,CHEN Wei,PAN Yi.Determination of Genotoxic Impurity Mesityl Oxide in Sofalcone by GC-MS/MS[J].Chin J Mod Appl Pharm(中国现代应用药学),2021,38(14):1686-1689.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 1110次   下载 510 本文二维码信息
码上扫一扫!
分享到: 微信 更多
GC-MS/MS测定索法酮中基因毒性杂质异亚丙基丙酮含量
丁文宇1,2, 雷勇胜1,2, 傅琳3, 穆帅1,2, 陈蔚1,2, 潘毅1,2
1.天津药物研究院有限公司原料药研发中心, 天津 300193;2.天津泰普制药有限公司技术研发中心, 天津 300193;3.天津药物研究院有限公司分析测试中心, 天津 300193
摘要:
目的 采用GC-MS/MS测定索法酮中基因毒性杂质异亚丙基丙酮的含量。方法 采用顶空进样法测定,色谱柱为Agilent DB-Heavy WAX (30 m×0.25 mm,0.25 μm),质谱检测器的离子源采用EI源,采集方式为选择性离子监测模式(SIM)。结果 异亚丙基丙酮在0.047 12~1.885 μg·mL–1(LOQ~200%)内浓度与峰面积线性关系良好(n=6),相关系数(r)为0.999 6,定量限为47.12 ng·mL–1,检测限为18.85 ng·mL–1,精密度RSD为1.43%。回收率为84.45%~91.58%,RSD为2.88%,溶液稳定性良好。结论 该方法简便准确,灵敏度高,耐用性好,适用于索法酮中异亚丙基丙酮含量的测定。
关键词:  GC-MS/MS  索法酮  异亚丙基丙酮  基因毒性杂质
DOI:10.13748/j.cnki.issn1007-7693.2021.14.004
分类号:R917.101
基金项目:“重大新药创制”国家科技重大专项(2009ZX09313-026)
Determination of Genotoxic Impurity Mesityl Oxide in Sofalcone by GC-MS/MS
DING Wenyu1,2, LEI Yongsheng1,2, FU Lin3, MU Shuai1,2, CHEN Wei1,2, PAN Yi1,2
1.Tianjin Institute of Pharmaceutical Research Co., Ltd., API R&D Center, Tianjin 300193, China;2.Technology R&D Center of Tianjin Taipu Pharmaceutical Co., Ltd., Tianjin 300193, China;3.Tianjin Institute of Pharmaceutical Research Co., Ltd., Analysis and Testing Center, Tianjin 300193, China
Abstract:
OBJECTIVE To establish an headspace sampling coupled with gas chromatography and mass spectrometry method for determination of genotoxic impurity mesityl oxide in sofalcone. METHODS The mesityl oxide in sofalcone was determined by HS-GC-MS with Agilent DB-Heavy WAX(30 m×0.25 mm, 0.25 μm) as stationary liquid capillary chromatographic column. The mass spectrometer was operated in the electron impact ionization(EI) fixed mode. The ion collection mode selected ion monitoring(SIM). RESULTS The linearity of the calibration curve was obtained by according peak area versus concentration of mesityl oxide within 0.047 12-1.885 μg·mL-1(LOQ-200%) with a regression coefficient(r=0.999 6), which had a good linear relationship. The limit of quantitation(LOQ) was 47.12 ng·mL-1, the limit of detection was 18.85 ng·mL-1. The RSD value of the precision was 1.43%. The recoveries with the range of 84.45%-91.58%, the RSD value was 2.88%. The sample solutions were very stability. CONCLUSION The method was convenient, accurate and had high sensitivity, good robustness, which was suitable for determination of mesityl oxide in sofalcone.
Key words:  GC-MS/MS  sofalcone  mesityl oxide  genotoxic impurity