Abstract:
OBJECTIVE To determine the content of epigoitrin, chlorogenic acid and liquiritin in child kechuanling granules by wavelength conversion HPLC. METHODS The sample was extracted by 70% methanol and separated on a Inertsil ODS-SP C
18(4.6 mm×250 mm, 5 μm). The mobile phase were 0.1% phosphoric acid and acetonitrile, gradient elution. The flow rate was 1.0 mL·min
-1 while the ultraviolet detector was operated at 245 nm(0-13 min) and 217 nm(13-52 min). RESULTS The linear range of epigoitrin, chlorogenic acid and liquiritin was respectively in 0.700-14.000 μg·mL
-1, 4.780-95.600 μg·mL
-1, 1.050-21.008 μg·mL
-1 while the average recovery was 98.8%, 102.8%, 97.7% with the RSD 1.2%, 1.9%, 1.4%(n=9). CONCLUSION This method is simple, rapid and with good repeatability, so it could be used in quality control of child kechuanling granules.